Combination arrester, type 1+2, N+PE for use in TN-S and TT networks.
MCD 125-B/NPE: Coordinated N-PE spark gap, type 1+2 to EN 61643-11. For interface 0 to 2 (LPZ) in accordance with lightning protection zone concept to IEC 61312-1 and/or VDE 0..
Surge arrester, type 2
• For surge voltage protection equipotential bonding to VDE 0100-443 (IEC 60364-4-44)
• Discharge capacity to 40 kA (8/20) per pole through high-performance varistors
• Modular connectable arrester with cut-off unit and..
Combination arrester, type 1+2, 1-pole, for use in TN and TT networks:
MCD 50-B-OS: Coordinated lightning current arrester, type 1+2 to EN 61643-11 with visual function display. For interface 0 to 2 (LPZ) in accordance with lightning protection ..
V25 combination arrester, type 1+2, for photovoltaic systems
• Complete unit, consisting of plug-in varistor arrester with cut-off unit
• Error-resistant Y circuit to VDE 0100-712 (EN 50539-12)
• Surge protection equipotential bonding to VDE 0..
Lightning current combination arrester, type 1+2
• For lightning current equipotential bonding to VDE 0185-305 (IEC 62305)
• Lightning current arresting capacity of 12.5 kA (10/350) per pole and up to 50 kA (10/350) in total
• Modular, plug-in..
Pluggable data line protection, type 1+2/D1+C2 for use in measurement and control technology
• Protection device for multi-wire systems
• Indirect shield earthing
• Frequency range up to 100 MHz
• Earthing via DIN rail or connection cable
• ..
V50 combination arrester, type 1+2, for photovoltaic systems
• Complete unit, consisting of plug-in varistor arrester with cut-off unit
• Error-resistant Y circuit to VDE 0100-712 (EN 50539-12)
• Surge protection equipotential bonding to VDE 0..
• Spark gap to VDE 0185-561-3 (IEC 62561-3)
• Ex certificate to ATEX
• Labelling to EN 60079-0/-1: II 2 G Ex db IIC T6 Gb
• Labelling to EN 60079-0/-31: II 2 D Ex td IIIC T80 °C Db IP67
• Ex certificate to IECEx
• Labelling to IEC 60079-0/-1: E..
Combination arrester, lightning and surge arrester type 1+2
• Complete unit consisting of upper part and base, pre-mounted and ready for connection
• Universally suitable for TN and TT systems
• With remote signalling and potential-free NO con..
Type 1+2 combination arrester according to EN 50539-11 for lightning and surge protection of PV systems.
• Lightning protection equipotential bonding according to IEC 62305 (VDE 0185-305)
• Surge protection according to IEC 60364-7-712 (VDE 01..
Combination arrester, lightning and surge arrester type 1+2
• Complete unit consisting of upper part and base, pre-mounted and ready for connection
• For TN systems
• Plug-in arrester with dynamic cut-off unit
• With visual function display
..
Coaxial data cable protection devices for transmission and reception technology
• With N-Connector, male/female
• High impulse current load capacity: 2.5 kA (10/350)
• Simple mounting (adapter), m = connector, w = socket
• Low protection level at..
Lightning current combination arrester, type 1+2
• For lightning current equipotential bonding to VDE 0185-305 (IEC 62305)
• Lightning current arresting capacity of 12.5 kA (10/350) per pole and up to 50 kA (10/350) in total
• Modular, plug-in..
Type 1+2 combination arrester for lightning and surge protection of PV systems.
• Lightning protection equipotential bonding according to IEC 62305 (VDE 0185-305)
• Surge protection according to IEC 60364-7-712 (VDE 0100-712)
• Arresting capa..
Lightning current combination arrester, type 1+2
• For lightning current equipotential bonding to VDE 0185-305 (IEC 62305)
• Lightning current arresting capacity of 12.5 kA (10/350) per pole and up to 50 kA (10/350) in total
• Modular, plug-in..
Combination arrester consisting of lightning current and surge arrester type 1+2
• Complete unit consisting of cover and base, pre-mounted and ready for connection
• Suitable for TN-S and TT network systems
• With audible signalling for funct..
Combination arrester, lightning and surge arrester type 1+2 to DIN EN 61643-11.
• For lightning protection equipotential bonding to VDE 0185-305 (IEC 62305)
• Lightning current arresting capacity 12.5 kA (10/350) per pole
• Universally suitab..
Lightning arrester type 1
• For lightning protection equipotential bonding to DIN EN 62305 (IEC 62305)
• Lightning current arresting capacity 35 kA (10/350) per pole
• Follow current extinguishing 50 kAeff, arrester back-up fuse up to 400 A g..
LightningController-Set, 3-pole, for use in TN-C networks:
Completely pre-terminated and ready for connection, consisting of:
Lightning current arrester, type 1, to EN 61643-11 for interface 0 to 1 (LPZ) according to lightning protection zone c..
Combination arrester, lightning current and surge arrester, type 1+2
• Protection level ≤ 1.5 kV
• For lightning protection equipotential bonding to VDE 0185-305 (IEC 62305)
• Lightning current arresting capacity to 75 kA (10/350), 3-pole
• L..
LightningController set, 4-pole, for use in TN-S and TT networks:
Completely pre-terminated and ready for connection, consisting of:
MC 50-B VDE: Lightning arrester, type 1 to EN 61643-11 for interface 0 to 1 (LPZ) according to lightning protec..
Protection set, lightning and surge arrester combination, type 1+2
• For lightning protection equipotential bonding to VDE 0185-305 (IEC 62305)
• Lightning current arresting capacity to 50 kA (10/350) per pole
• Arrester, connectable, incl. co..
Protection set, lightning and surge arrester type 1+2
• Arresting capacity 100 kA 10/350 µs, BET-tested
• Pre-mounted and ready for connection, incl. connecting bridges, labelled connection terminals
• With remote signalling and potential-fre..
Combination arrester, lightning current and surge arrester, type 1+2
• Protection level ≤ 1.5 kV
• For lightning protection equipotential bonding to VDE 0185-305 (IEC 62305)
• Lightning current arresting capacity up to 100 kA (10/350), 3+NPE
..