• Plate thickness to 5 mm
• For conductor routing transverse and longitudinal to plate
• With 4 hexagonal bolts M6 x 12
• Conforms to the requirements according to DIN VDE 0185-305 (IEC 62305)
• 271 Cu: with hexagonal bolts stainless steel (VA)..
• FangFix terminal, VA for RD 8 mm
• Tested with H (0185 kA) to DIN EN 305-62305
• Round conductor installed on the air-termination rod with only one screw
• Suitable for Ø 16 mm pipe air-termination rods..
• Suitable for wind loads according to Eurocode 1: DIN EN 1991-1-4
• From a free length of > 2.5 m, an additional fastening, e.g. insulated
spacer is recommended
• Last metre is tapered from Ø 16 mm to Ø 10 mm, material: AlMgSi
• Matches stand ..
• Suitable for wind loads according to Eurocode 1: DIN EN 1991-1-4
• From a free length of > 2.5 m, an additional fastening, e.g. insulated
spacer is recommended
• Ø 16 mm, aluminium
• For stand system with M16 internal thread..
• Meets the requirements of VDE 0185-305-3 (IEC/ EN 62305-3)
• Fit: Rd 8–10 x Rd 16 / FL 30
• With adapter plate
• Mounted with 4 hexagonal bolts M8 x 25 and 4 hexagonal nuts M8 made of rust-proof stainless steel (A2)..
• System consisting of FangFix block with edge protection and clamp
• FangFix clamp made of VA; complies with the requirements of VDE 0185-305 (IEC 62305)
• Min. 16 kg block of Ø 365 mm, high level of stability
• Quick and easy installation of air..
• Tele lightning protection system against direct lightning strikes into plants, such as biogas plants
• Consisting of air-termination rod and air-termination rod stand
• Please order concrete foot, edge protection and threaded rods separately..
• With 2 Fix contact clamping screws, nuts and serrated washers
• With pre-mounted pressure trough made of VA
• Corresponds to the requirements of VDE 0185-305 (IEC 62305)..
• With thread M16 x 20
• With connecting strap
• Including pre-mounted connector type 5001 DIN for round conductor Rd 8-10
• For stands with female thread M16..
Please refer to the mounting instructions for information on routing the OBO isCon® conductor.
• Highly voltage-resistant, insulated conductor
• Floating discharge-free
• Additional mechanical protection (black protective jacket)
• For mainte..
Please refer to the mounting instructions for information on routing the OBO isCon® conductor.
• Highly voltage-resistant, insulated arrester
• Protection against contact voltage during rain (VDE 0432-1 (IEC/EN 60060-1)
• Floating discharge-fr..
• For mounting Ø 10 mm air-termination rods up to an overall length of 1,000 mm
• Quick installation of air-termination rod in base using plug-in system
• Quick and easy installation..
• Incl. aluminium air-termination rod 1,000 mm long (Ø 10 mm)
• Quick mounting of the air-termination rod in the base using plug technology
• With Vario quick connector 249..